Skip to content

Hardware specs

The numbers below are the Omni Pro II controller’s hardcoded capacity ceilings: the protocol’s RequestProperties / RequestStatus ranges, the SystemStatus payload size, the .pca file’s fixed-size names tables, and every cap in clsCapOMNI_PRO_II.cs derive from these. They’re the reason OmniClientV1 chunks polls and uses the long-form RequestUnitStatus for unit numbers above 255 — see zone & unit numbering for the address layout that yields those high numbers.

References for everything on this page: HAI’s OmniPro II Product Specifications (part 20A00-2, 2012-10) and OmniPro II Installation Manual 3.2.

What the controller can address at most — these set the upper bounds for every typed entity in HA.

ObjectLimitNotes
Zones17616 onboard + 160 across expansion
Hardwire zone expansions (10A06)216 zones each → 32
Expansion enclosures (17A00)816 zones + 16 outputs each
Units (lighting addresses)511X-10 / ALC / HLC / outputs / flags combined
Areas8true partitioning
Thermostats (Omnistat2)64
Buttons (named macros)128
Lighting scenes128
Programs1500
User codes99
Messages128stored on panel
Consoles (LCD keypads)16
OmniTouch 5.7e (IP)16
Access control card readers16
Access cards / keytags99
Serial ports (onboard)5
Serial expansion total6with one expansion
12 V trigger outputs (with expansion)8 (136)
Vocabulary words (built-in)550plus custom vocabulary
Battery standby (typical)24 hourswith derated outputs (see below)
FieldValue
Built-in digital communicatoryes
Reporting formatsContact ID, 4/2, 3/1
Extra phone numbers for voice notify8
Ethernet portyes (built-in, 100 Mbit)
Flash memoryyes (field firmware updates)
Network portUDP and TCP on 4369 by default

From the installation manual’s Specifications chapter (p64).

ParameterValue
Mains120 VAC, 60 Hz, 60 W
Transformer24 VAC, 1.67 A, 40 VA
Battery (backup)12 V, 7 Ah, sealed lead-acid
Nominal DC bus10 – 13.7 VDC (≤0.5 Vpp ripple)
Low-voltage cut-out≈9 VDC
Device fusepolyfuse, 1.35 A
Horns fusepolyfuse, 1.35 A
Battery fusepolyfuse, 4.00 A

Polyfuses self-reset; no field replacement needed.

OutputMax current
AUX 12 V (one source)1.0 A
SWITCH 12 V (one source)1.0 A
CONSOLE bus1.0 A
OUTPUTS 1-8 (each)100 mA
Combined: AUX + SWITCH + CONSOLE + OUTPUTS 1-81.0 A total
INT HORN + EXT HORN combined1.0 A

If the install needs to run for 24 h on the backup battery alone:

Output groupCombined max
AUX 12 V + SWITCH 12 V + CONSOLE + OUTPUTS 1-8250 mA
INT HORN + EXT HORN300 mA

Typical current at nominal voltage:

  • Controller idle: 135 mA
  • LCD console: 35 mA backlight off, 100 mA backlight on
ItemDimensionsWeight
Controller (W × H × D)13″ × 13″ × 4.5″≈10 lb
LCD console (W × H × D)4.6″ × 4.5″ × 1.2″≈0.5 lb
ParameterRange
Operating temperature32 °F – 122 °F (0 °C – 50 °C)
Operating humidity10 – 95 % RH, non-condensing
  • UL Listed residential burglar + fire
  • SIA CP-01 compliant (false-alarm-reduction)
  • California Title 24 compliant
  • 3-year warranty (HAI)

Built-in (selectable at install time):

English (default), Latin American Spanish, European Spanish, Catalan, Italian, French, Traditional Chinese, Simplified Chinese.

PartDescription
20A00-2OmniPro II with steel enclosure
20A00-8OmniPro II on mounting plate (for structured-wiring cans)
20A00-21OmniPro II board only
10A06-116-zone hardwire expansion board
17A0016-zone / 16-output expansion enclosure
42A00-1Wireless receiver
45A00-1Wireless receiver (alt model)